Certificate
An ISO 9001:2015 Company
Call Us

FRP Canopy for Motors / Instrument / Canveyer Belt

Canopy

Canopy Stands by the to Cover / Protect / Guard. Plants run with many Movable / Immovable, Machine, Structure. Tools etc which need to be protecacted from

  1. Dust
  2. Heat
  3. Chemical
  4. Water …. Etc

To get the plant operational unintreruted or yield. Crescent PPG Lining Pvt Ltd can make the Canopyt as per the Client / Plant Requirement, but in genral offer for:

FRP Canopy for Motors
FRP Canopy for Motors

Motor are the Working Horse for Industry Cant Afford a Brake Down.To Save from Moisture, Duct, Unwanted Element etc.

Different type of Motors are used for different applications, orientation, usage, Cable Entry i.e. Vertical, Horizontal, Flame Proof etc. Need FRP Motor Canopy accordingly.

Many times the orientation of the Motors or the Locations where it will be used is:

There need to design the FRP Motor Cover accordingly

For General FRP Motor Guard are offered as per the Frame size, Where as many factors are there which leads to the Frame Size but as a Gide Lines below selection table can be used./p>

Where as other then standerd size we also offer the Canopy as per the site requirement and ensure to make an arrangement for the installation as per the Motor Installed on Tank Nozzle.

images

Canopy to be Considering Terminal Box Orientation Cable Entry Where to be installed, How it should rest or Hold with Motor Most Important Canopy should not be hurdle in Maintenance of Motor Proper Air Ventilation Has to be There for Motor

We offer the Canopy with due consideration of above Providing a Canopy is not an issue How it should be hold to safeguard the Terminal Box Fan Crescent has provided Umbrela Type Providing a Strip to hold from Motors Bolts

FRAMfRE SIZE

HORSE POWER

 

2900RPM

1450RPM

       1000RPM

Rate in Rs

80

1 TO 1.5

0.75 TO 1

0.5 TO 0.75

1032.00

90

2 TO 3

1.5 TO 2

1 TO 1.5

1080.00

100

4

3 TO 4

2

1260.00

112

5.5

5.5

3

1392.00

132

7.5 TO 10

7.5 TO 10

4TO 7.5

1740.00

160

15 TO 25

15 TO 25

10 TO 15

2340.00

180

30

25 TO 30

20

3180.00

200

40 TO 50

40

25 TO 30

3840.00

225

60

50 TO 60

40

4440.00

250

75

75

50

5820.00

280

100 TO 125

100 TO 125

60 TO 75

7020.00

315

150 TO 230

150 TO 230

100TO195

9480.00

355

320 TO 390

305 TO 365

245 TO 285

16560.00

SELECTION TABLE FOR NFLP MOTORS

Frame Size

Horse Power

3000rpm

1500rpm

1000rpm

80

1 to 1.5

0.75 to 1

0.5 to 0.75

90

2 to 3

1.5 to 2

1 to 1.5

100

4

3 to 4

2

112

5.5

5.5

3

132

7.5 to 10

7.5 to 10

4to 7.5

160

15 to 25

15 to 25

10 to 15

180

30

25 to 30

20

200

40 to 50

40

25 to 30

225

60

50 to 60

40

250

75

75

50

280

100 to 125

100 to 125

60 to 75

315

150 to 230

150 to 230

100to195

355

320 to 390

305 to 365

245 to 285

400

440 to 520

440 to 520

380 to 435

For FLP MOTORS- Please consider Thgher size of canopy

For H.T. MOTORS - Please the dimensions

images
Motor Canopy

Motor are the Working Horse for Industry Cant Afford a Brake Down..To Save from Moisture, Duct, Unwanted Element etc. FRP motor guard…

To Save from Moisture, Duct, Unwanted Element etc. FRP motor guard…

images
Instrument Canopy

Instrument Provide the Vital Intlegency to Run the Plant Mall function will lead to…

TFor it must be saved from Moisture, Dusct etc Need Canopy…..

images

Required special canopy

Instrument Canopy

Instrument Provide the Vital Intlegency to Run the Plant Mall function will lead to…

TFor it must be saved from Moisture, Dusct etc Need Canopy…..

Many types of Instruments are used to control or streamline the process:

  1. Temperature Transmitter
  2. pH Analyzers
  3. Pressure Transmitter
  4. Level Transmitter
  5. Flow transmitter
  6. And many more
Not only canopy should be design as per the application or requirement but also is important:
  1. How it will be installed
  2. How it should be hold.

So that should protect instrument at the same time easy for reading, regular maintenance etc.

In general the Canopy are made from UV Stablise General Purpose Resin in Iren Gray , whereas per client Specific Requirement can be offer:

  1. Fire Retardent
  2. ISO / Vinyl Ester

We design and provide the Instrument Canopy as per Client requirement

Crescent not only supply but provide the design for canopy as well as how to be installed….
Flange Mounted Canopy
Box Canopy Available. Door With Hinges as well as Sliding
Photo of Box Canopy with Sliding Door
Diagonal Box Type Canopy
Diagonal Long Canopy
Diagonal Open Canopy
Motors

Motors are the working Horse of the Industries, as per the requirement different Type of Motors are used for name: Single Phase, Three Phase, FLP, Non FLP and many more.

In general the FRP motor cover are available as per the Frame Size in Standerd Dimensions.

Where as other then standerd size we also offer the Canopy as per the site requirement and ensure to make an arrangement for the installation as per the Motor Installed on Tank Nozzle.

Instrument Canopy

In general the Canopy are made from UV Stablise General Purpose Resin in Iren Gray , whereas per client Specific Requirement can be offer:

  1. Fire Retardent
  2. ISO / Vinyl Ester

We design and provide the Instrument Canopy as per Client requirement

Instrument Canopy
images

Canopy to be design Considering Terminal Box Orientation Cable Entry Where to be installed, How it should rest or Hold with Motor Most Important Canopy should not be hurdle in Maintenance of Motor Proper Air Ventilation Has to be There for Motor

We offer the Canopy with due consideration of above Providing a Canopy is not an issue How it should be hold to safeguard the Terminal Box Fan Crescent has provided Umbrela Type Providing a Strip to hold from Motors Bolts

Chemical Storage Tank.

Nothing is inert if we talk about Chemical Resistant Material, the only thing is its react very slowly where we can expact the desired life.

While selection of material for the Chemical storage tank material to be selected carefully and further has to understand operational requirement along with design parameters.

We are one of the reputed FRP Tank Manufacturer, having more than 25 Yrs Experience in the Field.

Chemical Tanks are widely required to handle or store Chemicals and hence called Chemical Storage Tanks or Acid Tanks since many time its use for the Storage of the Acid.

Chemical Tanks are made-up from different composition:

  • PP FRP Storage Tanks or called as PP FRP Tank
  • FRP Tanks or FRP Vessels.
  • MS Tank with FRP Coating
  • MS Tank with Rubber Lining

All above has its prone and corns along with Commercial Implications on Prices.

The Important Factors which considered for the selection of the Material are:

  • Most Important is the Chemical to be handled.
  • Operation Conditions of the Vessels / Tanks, Temperature. Pressure etc.
  • Size / Capacity of the Chemical Storage Tank / Chemical Storage Vessel.
  • Orientation of the Chemical Tank / Vessels.
  • Location where to be installed as Weight of the Vessel and Tank, makes a difference if it has to be used at Height then the supporting structure and how it will be placed there.

Further details required by FRP Tank Suppliers for the designing of the tank is:

  • Density of the Chemicals.
  • Homogenous or Mix of the Chemicals will be poured in.
  • Conical Top / Open Top.
  • Horizontal / Vertical
  • Nozzle Orientation

FRP Tank Prices or Any other can be furnish only after receiving the above information.

As per the Requirement Combination of the Material can be used to avoid Unwanted Brake Down i.e.

  • MS FRP Tank with Acid Proof Tiles Lining.
  • MS Rubber Lining with Acid Proof Tiles
whatsapp
Chat with us